1. TECHNICAL DATA
This is a directly linked 1-cylinder compressor in mobile
design. This compressor is also equipped with a reducing
valve, a automatic shutdown and a quick coupling.
Sound pressure level 83,8 dB(A)
CAREFULLY READ THE INSTRUCTIONS
BEFORE YOU USE THE COMPRESSOR!
2. SPECIFIC SAFETY RULES
BEFORE USING THE COMPRESSOR:
1. Place the compressor in a well ventilated, frost
free area.
To obtain sufficient ventilation and cooling the distan-
ce between the shield and the wall needs to be at least
50 to 60 cm.
2. The following points need to be checked:
- do the voltage of the engine and the engine safe
guard, if any, correspond to the mains voltage (ap-
pliances for a mains voltage of 230 V can be connec-
ted to a mains voltage of 220 V without any pro-
blems);
- an earthed mains connection (wall socket) needs
to be used;
- are the mains lead and the mains plug in a good con-
dition: solid, without any loose ends or damage;
- the pressure reducing valve may not be copletely
closed so as to prevent damage to membranes;
- the oil level with help from the gauge. The oil level
should be within the area indicated by both marks
on the gauge, when the compressor is placed level.
-before use the air tank needs to be empty.
IMPORTANT: To prevent damage to the motor
windings as a result of voltage variation it is advisable
to mount an engine safety switch.
WHILE USING THE COMPRESSOR:
1. Do not use extension cables which are too long.
IMMEDIATELY SWITCH OFF THE COMPRES-
SOR IN CASE OF:
1. defective mains plug, mains line or damage to the
mains line;
2. defective switch;
3. smoke or bad smell caused by scorched insulation.
3. INSTALLATION
The compressor needs to be placed in well-ventilated,
frost-free area. To obtain sufficient ventilation and coo-
ling the distance between the shield and the wall needs to
be at least 50 to 60 cm.
4. OPERATING THE COMPRESSOR
- The mains switch needs to be in “OFF” or “0” posi-
tion before the mains plug is connected to the mains
voltage.
- Bij switching the switch to “ON” or “1” the compres-
sor will operate.
- Always keep the mains lead away from moving parts
of any linked up air-pressure equipment.
-With the use of the reducing valve it is possible to ad-
just the air pressure by hand. By pressing the reducing
valve the chosen position can be locked. However, do
not close the reducing valve too much, in order to
prevent damage to the membranes.
5. MAINTENANCE
The mains plug always needs to be taken out
of the socket (the mains socket) during main-
tenance or cleaning activities. Never use wa-
ter or other agressive liquids to clean the ma-
chine. Clean the machine by brushing it with
a brush.
PERIODIC MAINTENANCE OF THE COMPRES-
SOR WILL PREVENT UNNECESSARY PROBLEMS!
Oillevel
The compressor comes with a special test oil, that must
be Replaced after about 100 hours of use. Check the oil
level from time to time, using the oil gauge.
When the compressor is level and has not been used for
some time, the oil level should be within the area indica-
ted by both marks on the gauge. The oil must be replaced
after every 1000 hours of use. Use compressor oil API
CC SAE 40 rather than motor oil. If the compressor is
!
GB
English
Art.
nr.
Type
V~/Hz W RPM LTR. L/MIN BAR
231710 FC-710 230~50 1.500 2.800 50 245 8
1'
Exploded
view 2
FC-710
AVAILABLE SPARE PARTS FOR FC-710
REF.NR. DESCRIPTION FERM NR.
1 CYLINDER COVER (RED) 208217
2REAR COVER 208200
3 COVER 208201
6 VALVE PLATE 208252
7 FAN 208202
9 OIL LEVEL GAUGE 208203
11 CRANKSHAFT + AXLE 208204
8223091 CONNECTION ROD COMPLETE 208205
21 CONDENSOR 25 uF 800025
23 CYLINDER 208210
24 CYLINDER HEAD PACKING 208211
26 GASKET VALVE PLATE HEAD 208212
27 HEAD 208213
29 FILTER 205730
30 STATOR 208221
31 ROTOR 208222
32 CYLINDER PACKING 208216
Lataa käyttöohje suomalainen (PDF, 0.5 MB)
(Mieti ympäristöä ja tulosta tämä käyttöopas vain, jos se on todella tarpeen)

Loading…

Arviointi

Kerro meille mielipiteesi FERM CRM1005 FC-710 Kompressori arvioimalla tuote. Haluatko jakaa tuotekokemuksesi tai kysyä kysymyksen? Jätä kommentti sivun alalaidassa.
Oletko tyytyväinen kohteeseen FERM CRM1005 FC-710 Kompressori?
Kyllä Ei
Arvostele tuote ensimmäisenä
0 äänet

Keskustele tuotteesta

Täällä voit jakaa mielipiteesi FERM CRM1005 FC-710 Kompressori:sta. Jos sinulla on kysyttävää, lue ensin huolellisesti käyttöohje. Käsikirjaa voi pyytää yhteydenottolomakkeellamme.

Lisää tästä ohjekirjasta

Ymmärrämme, että on mukavaa, että sinulla on paperikäyttöinen käyttöopas laitteellesi FERM CRM1005 FC-710 Kompressori. Voit aina ladata oppaan verkkosivuiltamme ja tulostaa sen itse. Jos haluat alkuperäisen käyttöoppaan, suosittelemme ottamaan yhteyttä osoitteeseen FERM. He saattavat pystyä toimittamaan alkuperäisen ohjekirjan. Etsitkö laitteen FERM CRM1005 FC-710 Kompressori käyttöopasta toisella kielellä? Valitse haluamasi kieli kotisivuiltamme ja etsi mallinumero nähdäksesi, onko sitä saatavilla.

Tekniset tiedot

Tuotemerkki FERM
Malli CRM1005 FC-710
Kategoria Kompressorit
Tiedostotyyppi PDF
Tiedoston koko 0.5 MB

Kaikki käsikirjat kohteelle FERM Kompressorit
Lisää Kompressorit käsikirjoja

Käyttöohje FERM CRM1005 FC-710 Kompressori

Liittyvät tuotteet

Aiheeseen liittyvät luokat