Käyttöohje Elica Plat WH/F/80 Connex Liesituuletin

Tarvitsetko käyttöoppaan Elica Plat WH/F/80 Connex Liesituuletin? Alta voit katsoa ja ladata suomenkielisen PDF-oppaan ilmaiseksi. Tällä tuotteella on tällä hetkellä 3 usein kysyttyä kysymystä, 0 kommenttia ja 0 ääntä. Jos tämä ei ole haluamasi käyttöopas, ota meihin yhteyttä.

Onko tuotteessa vika, eikä käyttöoppaasta ole apua? Siirry Repair Café ‑alueelle etsimään ilmaisia korjauspalveluita.

Käyttöohje

Loading…

T7 LED Wi-Fi Status
White light flashing
slowly
Attempt to connect to the Elica
Cloud
White light on stea-
dy
Wi-Fi connected
White light on with
short flashing light
Command received from Elica
Cloud App: motor on or light on,
etc.
Filter saturation indicator
The hood indicates when maintenance is needed for the
filters.
Grease filter alarm (every 40 hours of use
approximately):
- with the hood switched off, by pressing any speed, the
keys T1+T2 light up for 10 seconds, indicating
maintenance of the grease filters.
- After carrying out maintenance on the grease filters, it is
necessary to reset by pressing keys T1+T2 for 2 seconds
while the alarm is displayed.
- The reset operation is confirmed if the LEDs of keys T1-
T2 flash quickly and then go out.
To deactivate the grease Filter Alarm function, proceed
as follows:
This alarm is normally active; to deactivate it, perform this
procedure:
with the hood switched off, press and hold keys T1-T2 -T3
at the same time: LEDs T1 T2 and T3 will light up with
different intensities from bright to soft; you will enter the
management menu of the grease Filter alarm, to
deactivate it press keys T1-T2 at the same time for 2
seconds.
Please note! The function is deactivated if T2 has LED
with a soft light; if the light of LED T2 is bright, the
operation must be repeated.
To reactivate the grease Filter Alarm function, repeat the
operation.
Activated carbon odour Filter Alarm (every 160 hours
of use approximately):
- with the hood switched off, by pressing any speed, the
keys T1+T3 light up for 10 seconds, indicating
maintenance of the activated carbon filters.
- After carrying out maintenance on the activated carbon
filters, it is necessary to reset by pressing keys T1+T3 for
2 seconds while the alarm is displayed.
- The reset operation is confirmed if the LEDs of keys T1-
T3 flash quickly and then go out.
Activation of activated carbon odour Filter Saturation
alarm.
This alarm is normally deactivated.
To activate it, proceed as follows:
with the hood switched off, press and hold keys T1-T2 -T3
at the same time: LEDs T1 T2 and T3 will light up with
different intensities from bright to soft; you will enter the
activation menu of the activated carbon odour filter
saturation indicator function, to activate it press keys T1-
T3 at the same time for 2 seconds.
Please note! The function is active if T3 has LED with a
bright light; if the light of LED T3 is soft, the operation must
be repeated.
- To deactivate the activated carbon odour Filter
Saturation function, repeat the operation.
MAINTENANCE WARNINGS
Cleaning: For cleaning, simply use a cloth moistened
with neutral liquid detergents. Do not use cleaning tools or
instruments.
Avoid the use of abrasive products. DO NOT USE
ALCOHOL!
For product maintenance, see the images at the
end of the installation marked by this symbol.
Anti-Grease Filter: The metallic anti-grease filter
must be cleaned once a month with non-aggressive
detergents, manually or in a dishwasher on a short wash at
low temperatures. To remove the anti-grease filter, pull the
spring release handle.
The Anti-Grease Filter traps the grease particles
produced during cooking. When cleaned in the dishwasher,
the metal grease filter may discolour, but its filtering
characteristics remain unchanged.
Washable activated carbon filter (for filter
version only):
The carbon filter can be washed every two months (or
when indicated by the filter saturation system - if included
in your model). As indicated in the drawing section: remove
the grease filter, remove the carbon filter and wash using
hot water and suitable detergents or in a dishwasher at
65°C (if washing in a dishwasher, carry out the complete
washing cycle without dishes inside). Remove any excess
water without damaging the filter, then place it in the oven
for 10 minutes at 100°C to dry it out completely. Put the
anti-grease filters back in place.
Replace the foam layer every 3 years and each time the
cloth appears damaged.
The carbon filter retains any unpleasant odours produced
during cooking. The saturation of the carbon filter can
occur after somewhat prolonged use depending on the type
of cooking and how regularly the grease filter is cleaned.
Illumination
The lighting system is based on LED technology. LEDs
provide optimal illumination, last up to 10 times longer than
conventional lamps and save 90% of electricity.
Lighting system : The lighting system cannot be
replaced by the user, contact Customer Service in case of
malfunction.

Lataa käyttöohje suomalainen (PDF, 13.27 MB)
(Mieti ympäristöä ja tulosta tämä käyttöopas vain, jos se on todella tarpeen)

Loading…

Arviointi

Kerro meille mielipiteesi Elica Plat WH/F/80 Connex Liesituuletin arvioimalla tuote. Haluatko jakaa tuotekokemuksesi tai kysyä kysymyksen? Jätä kommentti sivun alalaidassa.
Oletko tyytyväinen kohteeseen Elica Plat WH/F/80 Connex Liesituuletin?
Kyllä Ei
Arvostele tuote ensimmäisenä
0 äänet

Keskustele tuotteesta

Täällä voit jakaa mielipiteesi Elica Plat WH/F/80 Connex Liesituuletin:sta. Jos sinulla on kysyttävää, lue ensin huolellisesti käyttöohje. Käsikirjaa voi pyytää yhteydenottolomakkeellamme.

Lisää tästä ohjekirjasta

Ymmärrämme, että on mukavaa, että sinulla on paperikäyttöinen käyttöopas laitteellesi Elica Plat WH/F/80 Connex Liesituuletin. Voit aina ladata oppaan verkkosivuiltamme ja tulostaa sen itse. Jos haluat alkuperäisen käyttöoppaan, suosittelemme ottamaan yhteyttä osoitteeseen Elica. He saattavat pystyä toimittamaan alkuperäisen ohjekirjan. Etsitkö laitteen Elica Plat WH/F/80 Connex Liesituuletin käyttöopasta toisella kielellä? Valitse haluamasi kieli kotisivuiltamme ja etsi mallinumero nähdäksesi, onko sitä saatavilla.

Tekniset tiedot

Tuotemerkki Elica
Malli Plat WH/F/80 Connex
Kategoria Liesituulettimet
Tiedostotyyppi PDF
Tiedoston koko 13.27 MB

Kaikki käsikirjat kohteelle Elica Liesituulettimet
Lisää Liesituulettimet käsikirjoja

Usein kysytyt kysymykset kohteesta Elica Plat WH/F/80 Connex Liesituuletin

Tukitiimimme etsii hyödyllisiä tuotetietoja ja vastaa yleisiin kysymyksiin. Jos huomaat yleisissä kysymyksissä virheen, kerro siitä meille yhteydenottolomakkeella.

Kuinka etäällä liesituulettimeni pitää olla liesitasosta? Todennettu

Tämä voi hiukan vaihdella merkin mukaan, mutta yleensä liesituuletin tulee sijoittaa vähintään 65 cm:n etäisyydelle kaasukeittotasosta ja vähintään 50 cm:n etäisyydelle sähkö- tai induktiokeittotasosta. Se parantaa paloturvallisuutta.

Tästä oli apual (1346) Lue lisää

Tarvitsenko liesituulettimen moottorilla vai ilman? Todennettu

Moottorilla varustetut liesituulettimet on tarkoitettu, kun ilma siirretään suoraan ulkopuolelle. Liesituuletin ilman moottoria on tarkoitettu keskitettyyn ilmanvaihtojärjestelmään. Älä koskaan liitä liesituulettinta moottorilla keskitettyyn ilmanvaihtojärjestelmään!

Tästä oli apual (783) Lue lisää

Miten usein Elica-liesituulettimen aktiivihiilisuodatin täytyy vaihtaa? Todennettu

Aktiivihiilisuodatin tukkeutuu ajan mittaan esimerkiksi ruoanlaitosta kertyvän rasvan vuoksi. Elica suosittelee aktiivihiilisuodattimen vaihtamista kolmen kuukauden välein ihanteellisen toiminnan takaamiseksi.

Tästä oli apual (256) Lue lisää
Käyttöohje Elica Plat WH/F/80 Connex Liesituuletin

Liittyvät tuotteet

Aiheeseen liittyvät luokat

×
Download