Plug-In Energy Meter
Art.no 36-8705 Model E3182-V2
Please read theentire instruction manual before using theproduct and
then save it for future reference. Wereserve theright for any errors in
text or images and any necessary changes made to technicaldata.
Intheevent of technical problems or other queries, please contact our
Customer Services.
Safety
• Make sure that theelectrical socket that theproduct is plugged into
is easily accessible in case it and theconnected product need to be
quickly disconnected from themains electricity.
• Do not connect products of this type to each other.
• Do not cover theproduct.
• The product is intended only for use indoors.
• Devices connected to theelectricity meter should be of thesame
power rating and specifications.
Product Description
The energy meter measures how much electrical energy anelectric
device uses. Theenergy meter can calculate thetotal cost of running
adevice if theprice of each kWh is entered.
Thedisplay shows, amongst other things, thevoltage, power, energy
consumption, kWh and power factor of theconnected device. This
product should be connected to anearthed socket.
Instructions for use
Display
Changing thebatteries
If theenergy meter does not save thedata in its memory, thebatteries
should be changed.
1. Pull out theplastic tab protruding from thebattery
compartment. The energy meter will switch on.
2. Connect theenergy meter to anearthed wall socket.
3. Press [ SET ] to change thevalues displayed
on theENERGY and COST rows at thesame
time. Press [ ENERGY ] or [ COST ] to change
thedisplayed values separately.
Buttons and functions
1. [ SET ] Selects thedisplayed values, theelapsed
time is always displayed but theENERGY
and COST can be shown in 5 ways.
2. [ ENERGY ] Changes thevalue displayed on
theENERGY row.
3. [ COST ] Changes thevalue displayed on
theCOST row.
4. [ UP ] Changes thevalues.
a) Shows thetime elapsed since
aload device of at least 2 W has
been connected. The time stops
when thedevice is switched off
or theload is less than 2 W.
- The starting time is 0:00.
- Initially, thefirst digit represents
minutes, and after 10 minutes
thefirst two digits will represent
minutes and thetwo next digits
seconds.
- After 60 minutes, thefirst digit will represent hours and after 10 hours
two digits will represent hours and two digits minutes.
- After 24 hours thetime will start from 0:00 again and a1 will appear
after ‘Number of active days’ on theCOST row (c).
b) Shows electrical parameters. Press [ ENERGY ] to toggle between:
- Power (W)
- Voltage (V)
- Current (A)
- Frequency (Hz)
- Power factor. The power factor can be used to calculate thereactive
power VA by dividing theactive power W by thepower factor.
E.g. if theactive power is 30 W and thepower factor is 0.6,
thereactive power will be 50 VA (30/0.6=50).
c) Shows thecost and consumption. Press [ COST ] to toggle between:
- The total consumption in kWh
- The set electricity price, COST/kWh (theinitial electricity price value
is 1.00 COST/kWh)
- Number of active days
- CO
2
emission (based on 1kWh generating 0.998 kg CO
2
)
- Total cost
Setting theelectricity price
Can even be set when theenergy meter is plugged in.
1. Press [ COST ] for 3 seconds. The first digit will flash.
2. Press [ UP ] to change thevalue of thefirst digit and/or [ SET ] to move
to thenext digit.
3. Press [ COST ] or wait for 6 seconds to return to display mode.
1. Undo thetwo screws and
remove thebattery cover on
theback of themeter.
2. Remove theold LR44 batteries
and insert 2 new ones, making
sure thepolarity is correct.
3. Refit thebattery cover and
secure it with thescrews.
Care and Maintenance
Always remove theenergy meter from thewall socket before cleaning it.
Wipe with asoft, lightly moistened cloth. Use only mild cleaning agents,
never solvents or corrosive chemicals.
Responsible disposal
This symbol indicates that this product should not be
disposed of with general household waste. This applies
throughout theentire EU. In order to prevent any harm to
theenvironment or health hazards caused by incorrect
waste disposal, theproduct must be handed in for
recycling so that thematerial can be disposed of in
aresponsible manner. When recycling your product, take
it to your local collection facility or contact theplace of
purchase. They will ensure that theproduct is disposed of
in anenvironmentally sound manner.
Specifications
Rated voltage 230 V AC, 50 Hz
Max power 3680 W
Max current 16 A
Min measurable power Approx 2 W
Measuring ranges 175−276 V AC
2–3680 W
0.01–16 A
45−65 Hz
Operang temperature 0−50 °C
Baeries 2 × LR44